Wednesday, 27 March 2013

II Year PEE Unit-8 :Single phase induction motor bits

UNIT-VIII: Single phase induction motors




1. At starting, the line current of a capacitor start induction motor is ______ the normal full load current[ b ]
(a)8 to 10 times (b)4 to 5 times (c) equal to (d)7 to 8 times




2. The main winding and starting winding of a single phase induction motor are connected in__________ across the supply. [b ]
(a)series (b) parallel (c)series parallel (d)none


3. In capacitor start induction motor the angle between Im and Is is about 75˚


4. The purpose of starting winding in a single phase induction motor is to produce rotating flux


5. A single phase induction motor employs squirrel cage rotor


6. The main winding and starting winding of a single-phase induction motor are connected in ________ across the supply [b ]
(a) series (b) parallel (c) series-parallel (d) none of the above


7. A two-phase a.c. servometer has [b ]
(a) wound rotor (b) cage rotor (c) wound or cage rotor (d) a rotor similar to that in d.c motors


8. A 50 Hz, 4-pole, single-phase induction motor will have a synchronous speed of 1500 RPM


9. The full-load efficiency of a shaded-pole motor is about 30 to 35 %.


10. The amount of torque required to move a stepper motor one full step is called holding torque